Issue Date: November 22, 1995
Revision Date: June 25 2002
Veeder-Root
(originally listed as EnviroQuest Technologies Limited and later
as Watson Systems, Inc.)
Watson SIRAS Software
System Versions 2.0, 2.8.3
STATISTICAL INVENTORY
RECONCILIATION TEST METHOD (QUANTITATIVE)
Certification |
Leak rate of 0.2
gph with PD = 99.999% and PFA = 0.01%
Leak rate of 0.1 gph with PD = 99.3% and PFA = 0.7% |
Leak Threshold |
0.1 for leak rate
of 0.2 gph.
0.05 for leak rate of 0.1 gph.
A tank system should not be declared tight if the test result indicates a
loss or gain that equals or exceeds this threshold. |
Applicability |
Gasoline, diesel.
|
Tank Capacity |
Maximum of 30,000
gallons.
Size limits using an acceptable protocol for manifolded tank systems have
not been determined. |
Data Requirement |
Minimum of 30
days of usable product level and flow through data. |
System Features |
Backup technical
support for the end user was part of the service feature of these SIR
versions and was provided through contract with Watson Systems, Inc.
Since these SIR versions are now owned by Veeder-Root,
information, assistance, and technical support for these versions are at
their discretion. |
Comments |
Not evaluated for
in-house use that is independent of vendor participation.
Not evaluated for manifolded tank systems using an acceptable protocol. 27%
of data sets evaluated were from manifolded tank systems.
Of 56 data sets submitted for evaluation, 6 were not analyzed due to
unusable data.
Median monthly throughput for tanks evaluated was 73,518 gallons.
Leak rates ranging from 0.0458 to 0.2500 gph were used in evaluation.
Data sets evaluated were supplied by evaluator. |
Gilbarco/Veeder Root |
Evaluator: Midwest Research Institute |
Attn: CMS Mailstop F-76 |
Tel: (816) 753-7600 |
7300 West Friendly Ave. |
Date of Evaluation: 08/23/93 |
P.O. Box 22087 |
|
Greensboro, NC 27420-2087 |
|
Tel: (800) 253-8054 |
|
|