Issue Date: November 22, 1995
Revision Date: August 23, 1999

Universal Sensors and Devices, Inc.

Leak Alert System Models LAV-100, LA-01, LA-02, LA-04, LA-X4, LA-08, 
CATLAS with LAVS-1 MOS Vapor Sensor

OUT-OF-TANK PRODUCT DETECTOR (VAPOR-PHASE)

Detector:

Output type:

qualitative

Sampling frequency:

continuous

Operating principle:

metal oxide semiconductor

Test Results:

 

unleaded gasoline

synthetic gasoline

JP-4jet fuel

Detection time (sec)

31

40

42

Fall time (min:sec)

4:43

4:25

4:30

Lower detection limit (ppm)

100

N/D*

N/D

* See glossary.

Specificity Results (in addition to above):
Activated:  n-hexane, toluene, xylene(s).

 

Universal Sensors and Devices, Inc.

Evaluator: Carnegie Mellon Research Institute

9205 Alabama Ave., Unit C

Tel: (412) 268-3495

Chatsworth, CA 91311

Date of Evaluation: 06/01/94

Tel:  (800) 899-7121, (818) 988-7121       

 

 

 | Home | Vendors: A - F | Vendors: G - M | Vendors: N - S | Vendors: T - Z | Method Index | Glossary |

Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the method or equipment.
Equipment should be installed and operated in accordance with all applicable laws and regulations.  For full details, please refer to our expanded "DISCLAIMER" page.