Issue
Date: January 11,
2001
Simone
Engineering, Inc.
Magnetrol
Model 918 Ultrasonic Point Level Switch with ABB Automation Freelance 2000
Control System
INTERSTITIAL DETECTOR (LIQUID-PHASE)
Detector:
Output
type: |
qualitative,
non-discriminating |
Sampling
frequency: |
continuous |
Operating
principle: |
electrical
conductivity, ultrasonic |
Test Results:
|
trichloroethylene
|
acetone
|
water
|
Lower
detection limit (in)
|
0.143
|
0.166
|
0.164
|
Detection
time (sec)
|
<1
|
<1
|
<1
|
Fall
time (sec)
|
<1
|
<1
|
<1
|
Specificity
Results:
Evaluator claims sensors will
respond to any liquid after threshold is exceeded.
Comments:
The Magnetrol Model 918 has not
been evaluated for application with petroleum hydrocarbons.
The sensor has been evaluated specifically for application in water,
acetone, and trichloroethylene.
The
ABB Automation Freelance 2000 was used to detect the 8 to 16 milliamp change
that occurred in the Magnetrol sensor when it became submerged in product.
Audible and visual alarms were activated when the sensor indicated that
alarm conditions were present.
FCX Performance
|
Evaluator: Ken Wilcox
Associates
|
55 North Lively Blvd.
|
Tel: (816) 443-2494
|
Elk Grove Village, IL 60007
|
Date of Evaluation: 01/27/00
|
Tel: (847) 806-1885
|
|
E-Mail:
chill@FCxPerformance.com |
|
|