Issue Date: November 22, 1995
Revision Date: August 23, 1999
 

Mine Safety Appliances

Tankgard P/N 481532,Tankgard VIII P/N 488803

OUT-OF-TANK PRODUCT DETECTOR (VAPOR-PHASE)

 

Detector:           

Output type

quantitative

Sampling frequency

continuous

Operating principle

metal oxide semiconductor

Test Results:

 

benzene

2-methylbutane

Detection time (sec)

5

16

Fall time (min:sec)

04:12

04:42

Lower detection limit (ppm)

12.5

12.5

Specificity Results (in addition to above):
Activated (100%):  n-butane, n-hexane, 2-methylpentane, toluene, isobutane.

Manufacturer’s specifications:

Maximum Wire Distance

500 ft using 18 AWG

Response Time

30 seconds

Recovery Time

1 minute maximum

Sensor Life 2 year warranty

 

Mine Safety Appliances

Evaluator: Carnegie Mellon Research Institute

P. O. Box 427

Tel:  (412) 268-3495

Pittsburgh, PA 15230

Dates of Evaluation:  03/26/91, 03/28/91

Tel:  (800) 672-4678      

 

 

 | Home | Vendors: A - F | Vendors: G - M | Vendors: N - S | Vendors: T - Z | Method Index | Glossary |

Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the method or equipment.
Equipment should be installed and operated in accordance with all applicable laws and regulations.  For full details, please refer to our expanded "DISCLAIMER" page.