Issue Date: November 22, 1995 Gems Sensors Inc.
|
Output type |
qualitative |
Sampling frequency |
intermittent |
Test Results:
|
unleaded
gasoline |
synthetic
gasoline |
Detection time (min:sec) |
09:31 |
07:05 |
Fall time (min:sec) |
55:42 |
17:04 |
Lower detection limit (cm) |
0.04 |
0.08 |
Specificity Results (in
addition to above):
Activated:
n-hexane, diesel, jet-A
fuel, toluene, xylene(s).
Comments:
Sampling frequency
is designated as "intermittent" because polymer strip is permanently
mounted in monitoring well, while monitor is a hand held unit which is
periodically connected to sensor.
Sensors
are reusable.
Gems Sensors Inc. |
Evaluator: Carnegie Mellon
Research Institute |
1 Cowles Rd. |
Tel: (412) 268-3495 |
Plainville, CT 06062-1198 |
Date of Evaluation:
04/22/93 |
Tel: (800) 378-1600 |
|